Product Showcase

Videos | Product Specification Photos | MPGs | PDFs | Presentations | Product Catalogs

Videos

Click on an icon below to view a video...
Combined Heat and Power (CHP) Exhaust Heat Recovery
CHP Exhaust Heat Recovery
How a Boiler Economizer Works
How a Boiler Economizer Works
How Exhaust Heat Transfer Works
How Exhaust Heat Transfer Works!
DXL | Two Stage Exhaust Condensing Boiler Economizer
DXL | Two Stage Exhaust Condensing Boiler Economizer
CXL | Single Stage Exhaust Condensing Boiler Economizer
CXL | Single Stage Exhaust Condensing Boiler Economizer
RTR | Rectangular Tube Recovery Exhaust Heat Exchanger
RTR | Rectangular Tube Recovery Exhaust Heat Exchanger
FCR | Fin Coil Recovery Exhaust Heat Exchanger
FCR | Fin Coil Recovery Exhaust Heat Exchanger
EM | Energy Manager Exhaust Heat Exchanger
EM | Energy Manager Exhaust Heat Exchanger
HRSR | Heat Recovery Silencer Radial Cogeneration
HRSR | Heat Recovery Silencer Radial Cogeneration
UTR1 | U-Tube Recovery 1 Cogeneration Heat Recovery
UTR1 | U-Tube Recovery 1 Cogeneration Heat Recovery
ITR | Incinerator Tube Recovery Exhaust Heat Exchanger
ITR | Incinerator Tube Recovery Exhaust Heat Exchanger

Product Specification Photos (.pdf)

Click on an icon below to view a PDF of a product spec photo...

ESG1 - Exhaust Steam Generators

HRSR - Heat Recovery Silencer Radial Series

MPGs Archive (.mpg)

Selected product videos are available for you to download here. Additional interactive presentations and video footage is available on CD-ROM. Please contact us sales@cainind.com for more information.

ESG-636L18CSS High Performance Steam Generator

Capacity: 400kW - 7MW. Entering gas temperatures: 600°F - 1,600°F. Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. This model recovers heat from a natural gas fired incinerator and produces 228boiler HP steam @125psi.
Play Video (2:26 Minutes / 24 MB)

ESG1-816D17CSS High Performance Steam Generator

Capacity: 400kW - 7MW. Entering gas temperatures: 600°F - 1,600°F. Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam.
Play Video (2:43 Minutes / 23 MB)

ESG1-816D17CSS High Performance Steam Generator

Capacity: 400kW - 7MW. Entering gas temperatures: 600°F - 1,600°F. Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam.
Play Video (7:33 Minutes / 76 MB)

ESG1-820D17CSS High Performance Steam Generator

Capacity: 400kW - 7MW. Entering gas temperatures: 600°F - 1,600°F. Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. Shown installed at The Museum of Science and Industry in Chicago, IL.
Play Video (0:48 Minutes / 8 MB)

ESG1-616B19CSS High Performance Steam Generator

Capacity: 400kW - 7MW. Entering gas temperatures: 600°F - 1,600°F. Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. Shown in medical center installation. Recovering heat from Jenbacher JMS-320 900kW natural gas engines.
Play Video (0:31 Minutes / 5 MB)

ESG1-616D18CSS High Performance Steam Generator

Capacity: 400kW - 7MW. Entering gas temperatures: 600°F - 1,600°F. Heat sink types: Supplemental steam demand and/or primary steam source for steam heating or process steam. Recovering heat from Cummins QSV91.
Play Video (1:50 Minutes / 15 MB)

FCR-1M2A16ALS Cylindrical Boiler Economizers

Capacity: 50 - 10,000 scfm. Entering gas temperature up to 1,400°F. Heat sink types: Boiler feedwater, makeup water, process water, potable water, thermal fluids, run-around systems. Shown in printing plant installation.
Play Video (0:15 Minutes / 2 MB)

HRSR-3Z2H22.6CSS Radial Design Waste Heat Recovery Silencer

Capacity: 200kW - 6MW. Entering gas temperatures up to 1,250°F. Heat sink types: Engine jacket water, process water, boiler water, or glycol. These horizontal models recovers heat from Wartsilla 18V32BF, 5.8Mw engines.
Play Video (1:42 Minutes / 15 MB)

HRSR-230B26CSP Radial Design Waste Heat Recovery Silencer

Capacity: 200kW - 6MW. Entering gas temperatures up to 1,250°F. Heat sink types: Engine jacket water, process water, boiler water, or glycol. Vertical units shown here recover heat from Cummins QSK60 diesel engines at a Siberian power plant.
Play Video (2:37 Minutes / 26 MB)

HRSR-330C26SSP Radial Design Waste Heat Recovery Silencer

Capacity: 200kW - 6MW. Entering gas temperatures up to 1,250°F. Heat sink types: Engine jacket water, process water, boiler water, or glycol. Six vertical units shown here recover heat from Cat 3516 engines.
Play Video (1:16 Minutes / 13 MB)

HRSR-230C Radial Design Waste Heat Recovery Silencer

Capacity: 200kW - 6MW. Entering gas temperatures up to 1,250°F. Heat sink types: Engine jacket water, process water, boiler water, or glycol. These horizontal models recover heat from engines at the American Embassy in Afghanistan.
Play Video (3:19 Minutes / 34 MB)

HRSR-324B26CSP and HRSR-324826CSP Radial Design Waste Heat Recovery Silencer

Capacity: 200kW - 6MW. Entering gas temperatures up to 1,250°F. Heat sink types: Engine jacket water, process water, boiler water, or glycol. These vertical models recover heat from 3 diesel generators at a power plant.
Play Video (2:19 Minutes / 24 MB)

RTR Rectangular Tube Waste Heat Recovery

Capacity: to 40,000pph (50,000,000Btu/hr input. Entering gas temperatures 300°F to 1,250°F. Heat sink types: Boiler feedwater, makeup water, hot water return, hot water storage tank, condensate tank, process water, potable water. Shown: Large vertical unit
Play Video (0:29 Minutes / 4 MB)

UTR1-814G16CSP U-Tube Recovery Unit

This recovery unit is used primarily where confined area restrictions vs heat transfer requirements must be considered as a priority.

Capacity: 200kW - 10MW. Entering gas temperatures up to 1,600°F. Heat sink types: Process water, boiler feedwater, glycols, thermal transfer fluids. Recovering heat from a 1500kW Fairbanks Morse natural gas engine.
Play Video (0:49 Minutes / 7 MB)

Sootblower

This video demonstrates the exclusive Cain Fully Automatic Modulating Sootblower. Shown here on a smaller vertical RTR model.
Play Video (0:26 Minutes / 4 MB)

PDF Archive (.pdf)

Exhaust Steam Generator (ESG1)

Capacity: 400 to 7MW | Entering Gas Temps: 600°F to 1,600°F
Heat Sinks: supplemental steam demand and/or primary steam source for steam heating or process steam
Download PDF (500 KB)

Heat Recovery Silencer - Radial (HRSR)

Capacity: 200kW to 6MW | Entering Gas Temps: 450°F to 1,250°F
Heat Sinks: engine jacket water, process water and ethylene glycol
Download PDF (655 KB)

Heat Recovery Silencer - Axial (HRSA)

Capacity: 5 to 150kW | Entering Gas Temps: 450°F to 1,250°F
Heat Sinks: engine jacket water, process water, boiler water and ethylene glycol
Download PDF (440 KB)

U-Tube Recovery System (UTR)

Capacity: 15 to 300kW | Entering Gas Temps: 450°F to 1,600°F
Heat Sinks: engine jacket water, process water, boiler water, ethylene glycol and thermal transfer fluids
Download PDF (370 KB)

U-Tube Recovery Unit 1 (UTR1)

Capacity: 200kW to 10MW | Entering Gas Temps: 450°F to 1,600°F
Heat Sinks: process water, boiler feedwater, ethylene glycol and thermal transfer fluids
Download PDF (1.4 MB)

Cogen Accessories

Cain offers several system-compatible accessories including ebullient steam generators, boiler feedwater systems and unique bypass valves. In addition Cain offers a line of exclusive time automatic sootblowers, which provide unmatched industry performance.
Download PDF (88 KB)

Rectangular Tube Recovery System (RTR)

Combustion Capacity: 5,000 to 250,000 pph (300,000,000 BTU/hr maximum input approx.) | Entering Gas Temps: 300°F to 800°F
Heat Sinks: boiler feedwater, makeup water, hot water return hot water storage tank, condensate tank, process water
Download PDF (1.6 MB)

Fin Coil Recovery System (FCR)

Combustion Capacity: 50 to 10,000 (scfm) 40 to 500 BHP | Entering Gas Temps: Up to 800°F
Heat Sinks: boiler feedwater, process water, thermal fluids and run-around systems
Download PDF (160 KB)

B Series Boiler Economizer

Combustion Capacity: 40 to 800 BHP | Entering Gas Temps: 300°F to 700°F
Heat Sinks: boiler feedwater, hot water return, hot water storage tank, condensate tank and process water
Download PDF (160 KB)

Energy Manager (EM)

Combustion Capacity: 200,000 to 6,400,000 BTU/hr input | Entering Gas Temps: 300°F to 700°F
Heat Sinks: boiler feedwater, hot water return, hot water storage tank, condensate tank and process water
Download PDF (170 KB)

Packaged Boiler Feed Systems

Cain Industries produces feed systems with feedwater pumps, water softeners, and chemical feed all pre-piped and pre-wired. This packaged system minimizes installation and startup expenses.
Download PDF (400 KB)

Product Presentations (Windows .exe files)

Selected Cain Industries interactive presentations are available for you to download here. Additional presentations, including a compilation disc, are available on a FREE CD-ROM

Complete Cain Industries Product Line

This presentation includes: Cain Solutions (company overview), Gas & Diesel Cogeneration Systems, Boiler Economizer Systems, Fume Incineration Systems, and Finned Tubing.
Download Presentation (123 MB)

ESG-636L18CSS Presentation

One of several components supplied by Cain Industries for a complex application. This ESG recovers 7,636,500 Btu/hr from a natural gas fired incinerator,producing 228 boiler HP at 125psi for an annual cost savings of more than $200,000.
Download Presentation (26 MB)

ESG1-820D17CSS and ESG1-616D18CSS Presentation

Reducing exhaust gas temperature from 941°F to 346°F at 4,761 SCFM with 1.71WC" pressure drop. Recovering 3,467,300Btu/hr. Saving $138,690 annually.

Reducing exhaust gas temperature from 912°F to 422°F at 4,587SCFM with a 1.5WC" pressure drop. Recovering 1,800,000Btu/hr.
Download Presentation (36 MB)

FCR-1M2A16ALS Presentation

Recovering 630,128 Btu/hr from 500HP boilers. Reducing exhaust gas from 400 °F to 263°F. at 4,205 SCFM. Annual cost savings of $96,816.
Download Presentation (72 MB)

HRSR-3Z2H22.6CSS Horizontal Presentation

Recovering 7,764,000 Btu/hr at 15,857 SCFM. Reducing exhaust gas from 716 °F to 310 °F. Annual cost savings of over $100,000.
Download Presentation (24 MB)

HRSR-32428CSP and HRSR-330C28CSP Presentation

(2) HRSR-32428CSP, recovering heat from Cat 3516 1200rpm engine - lowering exhaust temp from 904 °F to 358 °F. (1) HRSR-330C28CSP, recovering heat from Cat 3516B 1800 rpm engine - lowering exhaust temp from 979 °F to 374 °F. Combined recovery of 5,010,000Btu/hr for an annual savings of over $150,000
Download Presentation (23 MB)

RTR-1V2126.7CSS Horizontal Presentation

Reducing exhaust gas from 509°F to 343°F. at 14,047 SCFM. Recovering 3,451,700 Btu/hr for an annual cost savings of $96,816.
Download Presentation (8 MB)

RTR-1Y2128CSS Vertical Presentation

Retrofitting a 150,000 lb/hr boiler and reducing exhaust gas from 635 °F to 369°F. at 36,521 SCFM. Recovering 1,716,000 Btu/hr for an annual cost savings of $403,000.
Download Presentation (59 MB)

UTR1-814G16CSP Presentation

Recovering heat from Fairbanks-Morse natural gas fired engines. Reducing exhaust gas temperature from 645°F to 357°F at 6,739 SCFM with a 2WC" pressure drop. Raising liquid from 250°F to 263.3°F at 400GPM. Recovering 2,340,700Btu/hr, saving $60,000 annually.
Download Presentation (12 MB)